QMI3472 |
 |
|
SANblade® QMI3472 Dual Port 4-Gbps Fibre Channel (FC) & 1-Gbps Ethernet CFFh Expansion Card for IBM BladeCenter IBM Part Number: 39Y9306. | |
|
|
|
|
 |
QME2462 |
 |
|
SANblade® QME2462 Dual Port 2-Gbps Fibre Channel (FC) HBA for Dell PowerEdge® 1855 and 1955 Blade Servers. | |
|
|
|
|
|
|
| |
| QMI3472 Fibre Channel Expansion Card |
|
The QMI3472 is the industry’s first multi-protocol expansion card enabling 4-Gbps Fibre Channel and 1-Gbps Ethernet in a PCI Express Combo Form Factor (CFFh) for the IBM BladeCenter. The QMI3472 not only delivers unprecedented levels of performance and availability, but also provides intelligent networking features specific to enterprise class data centers.
|
| Enterprise Class Features |
The QMI3472 delivers unmatched Fibre Channel and Ethernet performance, providing over 300,000 IOPS, nearly 1.6 GBps FC throughput, 1-Gbps full-duplex Ethernet, and support for PCI Express x4 bus speeds. More importantly, the QMI3472 HBA provides new intelligent storage networking features that redefine the enterprise class HBA, providing increased data protection, advanced frame routing, and enterprise wide management capabilities. |
| Simplified Setup |
|
Point-and-click installation and configuration wizards simplify the HBA setup process. Storage administrators can quickly deploy HBAs across a SAN using QLogic SANsurfer HBA management tools and device utilities, as well as configure and manage their Ethernet connections using the Broadcom® Advanced Control Suite (BACS). The QMI3472 is also fully compliant with industry standard Application Programming Interfaces (APIs), including SNIA HBA API and SMI-S. This compatibility allows administrators to manage QLogic HBAs using third-party software applications. |
| Comprehensive Operating System Support |
|
QMI3472 drivers exist for all major operating systems. A single FC driver strategy per OS allows storage administrators to easily deploy and manage HBAs in heterogeneous SAN configurations. In addition, QLogic’s unique unified driver model, whereby firmware is bundled with the driver, eliminates any potential interoperability issues between the driver and firmware and reduces the number of software components to be managed by SAN administrators. Ethernet drivers are available on IBM’s website. |
| Guaranteed Interoperability |
Storage partner certifications, combined with agency and regulatory testing, ensures all products meet world compliance hardware and software specifications. All our HBAs are tested extensively with third-party hardware, along with multiple software applications, to ensure best-in-class SAN and Ethernet interoperability and compatibility. |
| | | |
|
|
|
|
|
| |
| QME2462 Fibre Channel HBA |
|
The QME2462 enables 2-Gbps Fibre Channel in Dell PowerEdge blade servers. The QME2462 not only delivers unprecedented levels of performance and availability, but also intelligent networking features specific to enterprise class data centers.
|
| Enterprise Class Features |
The QME2462 delivers unmatched performance by leveraging a single ASIC design, combining a unique hardware architecture to deliver over 300,000 IOPS, nearly 800 MBps overall throughput, and support for PCI Express x4 bus speeds. More importantly, the QME2462 HBA provides new intelligent storage networking features that redefine the enterprise class HBA, providing increased data protection, advanced frame routing, and enterprise wide management capabilities. |
| Simplified Setup |
|
Point-and-click installation and configuration wizards simply the HBA setup process. Storage administrators can quickly deploy HBAs across a SAN using QLogic SANsurfer HBA management tools and device utilities. The QME2462 is also fully compliant with industry standard Application Programming Interfaces (APIs), including SNIA HBA API and SMI-S. This compatibility allows administrators to manage QLogic HBAs using third-party software applications. |
| Comprehensive Operating System |
|
Support. QME2462 drivers exist for all operating systems supported by Dell PowerEdge blade servers. A single driver strategy per OS allows storage administrators to easily deploy and manage HBAs in heterogeneous SAN configurations. In addition, QLogic’s unique unified driver model, whereby firmware is bundled with the driver, eliminates any potential interoperability issues between the driver and firmware and reduces the number of software components to be managed. |
| Guaranteed Interoperability |
Storage partner certifications, combined with agency and regulatory testing, ensures all products meet world compliance hardware and software specifications. All HBAs are tested extensively with third-party hardware, along with multiple software applications, to ensure best-in-class SAN interoperability and compatibility. You can be confident purchasing QLogic HBAs to meet your FC storage networking needs. |
| | | |
|
|
|
|
|
| |
| High Performance |
- 300,000 IOPS delivers high I/O transfer rates for storage applications
- Intelligent interleaved DMA (iiDMA) ensures maximum utilization of FC data links
- Out-of-Order Frame Reassembly (OoOFR) reduces FC congestion and retransmissions
- CPU off-load for TCP/IP checksum calculation and jumbo frame support (9 KB) reduces CPU utilization and increases Ethernet throughput
|
| Superior Scalability |
- Multi-ID and N_Port virtualization ready. Allows physical ports to be part of multiple logical networks
- Virtual fabric (VSAN) ready. Allows physical FC ports to be part of multiple logical networks
- Comprehensive operating system (OS) driver support including Windows, Linux, Solaris, NetWare, and VMware
|
| Enhanced Reliability |
- Overlapping protection domains for continuous protection of internal data paths
- Dual-port design protects against “single point of failure” via BladeSystem midplane routing to redundant switch modules.
| | |
|
|
|
|
|
| |
| High Performance |
- 300,000 IOPS (150,000 IOPS per port) delivers high I/O transfer rates for storage applications
- Intelligent interleaved DMA (iiDMA) ensures maximum utilization of data links
- Out-of-Order Frame Reassembly (OoOFR) reduces congestion and retransmissions
|
| Superior Scalability |
- Multi-ID and N_Port virtualization ready. Allows physical ports to be part of multiple logical networks
- Virtual fabric (VSAN) ready. Allows physical ports to be part of multiple logical ports
- Comprehensive Operating System (OS) driver support including Windows®, Linux™, and VMware®
|
| Enhanced Reliability |
- Overlapping protection domains for continuous protection of internal data paths
| | |
|
|
|
|
|
| |
|
Host Bus Interface Specifications |
| Bus interface |
|
Dual PCI Express x4 |
| Memory |
|
1-MB flash and 128-KB flash (SPI)
2-KB NVRAM (SPI)
4-KB EEPROM (I2C) |
| Hardware platforms |
|
IBM HS21
IBM LS21
IBM LS41 |
| Compliance |
|
PCI Express Base Specification, revision 1.0a
PCI Bus Power Management Interface Specification, revision 1.1 |
| Fibre Channel Specifications |
| Data rate |
|
4/2/1 Gbps auto-negotiation (4.25/2.125/1.0625 Gbps) |
| Performance |
|
150,000 IOPS per port |
| Topology |
|
Point-to-point (N_Port)
Arbitrated loop (NL_Port)
Switched fabric (N_Port) |
| Logins |
|
Support for F_Port and FL_Port login
2,048 concurrent logins and 2,048 active exchanges per port |
| Protocols |
|
FCP (SCSI-FCP)
FC-TAPE (FCP-2) |
| Compliance |
|
SCSI-3 Fibre Channel Protocol (SCSI-FCP)
Fibre Channel Physical and Signaling Interface (FC-PH)
Fibre Channel Physical and Signaling Interface 2nd Generation (FC-PH-2)
Third Generation Fibre Channel Physical and Signaling Interface (FC-PH-3)
Fibre Channel-Arbitrated Loop (FC-AL-2)
Fibre Channel Fabric Loop Attachment Technical Report (FC-FLA)
Fibre Channel-Private Loop Direct Attach Technical Report (FC-PLDA)
Fibre Channel Tape (FC-TAPE) profile
SCSI Fibre Channel Protocol-2 (FCP-2)
Second Generation FC Generic Services (FC-GS-3)
Third Generation FC Generic Services (FC-GS-3)
Fibre Channel Framing and Signaling (FC-FS) |
| Ethernet Specifications |
| Data rate |
|
1-Gbps full-duplex per port |
| Topology |
|
Any Ethernet network |
| Physical Specifications |
| Ports |
|
Dual 4-Gbps FC & dual 1-Gbps Ethernet |
| Form factor |
|
IBM Combo Form Factor (CFFv) |
| Environment and Equipment Specifications |
| Airflow |
|
No airflow required |
| Temperature |
|
Operating: 0°C/32°F to 55°C/131°F
Storage: -40°C/-40°F to 70°C/158°F |
| Humidity |
|
Relative (non-condensing): 5% to 95%
Storage: 5% to 95% |
| Power dissipation |
|
6.8W (maximum) |
| Tools and Utilities |
| Management tools |
|
SANsurfer FC HBA Manager
SANsurfer FC HBA Command Line Interface (CLI)
Broadcom Advanced Control Suite (BACS) |
| Device utilities |
| FLASUTIL for updating: Firmware, Boot code, HBA parameters |
| Boot support |
|
BIOS, FCode, PXE Ethernet Boot |
| APIs |
|
SNIA HBA API V2, SMI-S, and FDMI |
| Operating systems* |
|
Windows, Linux – Red Hat, Linux – SuSE, VMware, NetWare, Solaris |
| |
| * Subject to availability of OS and hardware from respective OEMs. | | |
|
|
|
|
|
| |
|
Host Bus Interface Specifications |
| Bus interface |
|
PCI Express x4 |
| Memory |
|
1-MB SRAM per port
1-MB flash (SPI)
2-KB NVRAM (SPI)
2-KB EEPROM (I2C) |
| Hardware platforms |
|
Dell PowerEdge 1855
Dell PowerEdge 1955 |
| Compliance |
|
PCI Express Base Specification, rev. 1.0a
PCI Bus Power Management Interface Specification, revision 1.1 |
| Fibre Channel Specifications |
| Data rate |
|
2/1 Gbps auto-negotiation (2.125/1.0625 Gbps) |
| Performance |
|
150,000 IOPS per port |
| Topology |
|
Point-to-point (N_Port)
Arbitrated loop (NL_Port)
Switched fabric (N_Port) |
| Logins |
|
Support for F_Port and FL_Port login
2,048 concurrent logins and 2,048 active exchanges per port |
| Protocols |
|
FCP (SCSI-FCP)
FC-TAPE (FCP-2) |
| Compliance |
|
SCSI-3 Fibre Channel Protocol (SCSI-FCP)
Fibre Channel Physical and Signaling Interface (FC-PH)
Fibre Channel Physical and Signaling Interface 2nd Generation (FC-PH-2)
Third Generation Fibre Channel Physical and Signaling Interface (FC-PH-3)
Fibre Channel—Arbitrated Loop (FC-AL-2)
Fibre Channel Fabric Loop Attachment Technical Report (FC-FLA)
Fibre Channel—Private Loop Direct Attach Technical Report (FC-PLDA)
Fibre Channel Tape (FC-TAPE) profile
SCSI Fibre Channel Protocol-2 (FCP-2)
Second Generation FC Generic Services (FC-GS-3)
Third Generation FC Generic Services (FC-GS-3)
Fibre Channel Framing and Signaling (FC-FS) |
| Physical Specifications |
| Ports |
|
Dual 2-Gbps Fibre Channel |
| Form factor |
|
Dell PowerEdge mezzanine card |
| Environment and Equipment Specifications |
| Airflow |
|
No airflow required |
| Temperature |
|
Operating: 0°C/32°F to 55°C/131°F
Storage: -40°C/-40°F to 70°C/158°F |
| Humidity |
|
Relative (non-condensing): 5% to 95%
Storage: 5% to 95% |
| Power dissipation |
|
4.7W (maximum) |
| Tools and Utilities |
| Management tools |
|
SANsurfer FC HBA Manager
SANsurfer FC HBA Command Line Interface (CLI) |
| Device utilities |
| FLASUTIL for updating: Firmware, Boot code, HBA parameters |
| Boot support |
|
BIOS |
| APIs |
|
SNIA HBA API V2, SMI-S, and FDMI |
| Operating systems* |
|
Windows Server®, Linux – Red Hat®, Linux – SuSE®, VMware |
| |
| * Subject to availability of OS and hardware from respective OEMs. | | |
|
|
|
| |
OEM Branded Product |
| |
|
Customized for QLogic’s server and storage OEM customers |
| OEM |
OEM Model Name |
Where to Buy?** |
|
IBM |
39Y9306 |
www.ibm.com | |
|
|
|
|
** Contact appropriate server or storage OEM for information on pricing, contents, warranty, and placing orders. | |
|
|
|
| |
OEM Branded Product |
| |
|
Customized for QLogic’s server and storage OEM customers |
| OEM |
OEM Model Name |
Where to Buy?** |
|
Dell |
CN040 |
www.dell.com | |
|
|
|
|
** Contact appropriate server or storage OEM for information on pricing, contents, warranty, and placing orders. | |
|
|
|
|
|
|
|
|
|
|
Brochures &
White Papers |
|
|
|